Measurement of photoneutron spectrum at Pohang Neutron Facility
SCIE
SCOPUS
- Title
- Measurement of photoneutron spectrum at Pohang Neutron Facility
- Authors
- Kim, GN; Kovalchuk, V; Lee, YS; Skoy, V; Cho, MH; Ko, IS; Namkung, W; Lee, DW; Kim, HD; Ko, SK; Park, SH; Kim, DS; Ro, TI; Min, YG
- Date Issued
- 2002-06-11
- Publisher
- ELSEVIER SCIENCE BV
- Abstract
- The Pohang Neutron Facility, an electron linear accelerator (linac) based pulsed neutron facility. was constructed for nuclear data production in Korea. It consists of an electron linac, a water-cooled Ta target with a water moderator, and a time-of-flight path with an I I m length. The neutron energy spectra are measured for different water levels inside the moderator and compared with calculations by the Monte Carlo N-Particle transport code. The optimum size of the water moderator is determined based on these results. (C) 2002 Elsevier Science B.V. All rights reserved.
- Keywords
- Pohang Neutron Facility; pulsed neutron source; water-cooled Ta target; MCNP; photoneutron spectra; time-of-flight method
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/108157
- DOI
- 10.1016/S0168-9002(01)02115-5
- ISSN
- 0168-9002
- Article Type
- Article
- Citation
- NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, vol. 485, no. 3, page. 458 - 467, 2002-06-11
- Files in This Item:
- There are no files associated with this item.