Three-dimensionally crossing manifold micro-mixer for fast mixing in a short channel length
SCIE
SCOPUS
- Title
- Three-dimensionally crossing manifold micro-mixer for fast mixing in a short channel length
- Authors
- Lim, TW; Son, Y; Jeong, YJ; Yang, DY; Kong, HJ; Lee, KS; Kim, DP
- Date Issued
- 2011-01
- Publisher
- ROYAL SOC CHEMISTRY
- Abstract
- In this study, we report a neo-conceptive three-dimensionally (3D) crossing manifold micromixer (CMM) embedded in microchannel. Fabricated by sequential processes of photolithography and two photon absorption stereolithography, this leads to a microfluidic system with a built-in micromixer in a site controlled manner. The effectiveness of CMM is investigated numerically and experimentally. Through the numerical simulation, it is estimated that a high mixing ratio of 90% can be obtained even in a channel length shorter than five times the channel width. This compares well with the conventional passive type of micromixers that have a gradual increase in mixing efficiency with the length of the channel. Furthermore, the mixing performance of the realized CMM built-in microchannel is observed by confocal microscopy.
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/11332
- DOI
- 10.1039/C005325M
- ISSN
- 1473-0197
- Article Type
- Article
- Citation
- LAB ON A CHIP, vol. 11, no. 1, page. 100 - 103, 2011-01