DC Field | Value | Language |
---|---|---|
dc.contributor.author | 소재인 | - |
dc.date.accessioned | 2024-08-23T16:33:00Z | - |
dc.date.available | 2024-08-23T16:33:00Z | - |
dc.date.issued | 2024 | - |
dc.identifier.other | OAK-2015-10630 | - |
dc.identifier.uri | http://postech.dcollection.net/common/orgView/200000806038 | ko_KR |
dc.identifier.uri | https://oasis.postech.ac.kr/handle/2014.oak/124020 | - |
dc.description | Master | - |
dc.description.abstract | Tuberculosis (TB), the leading cause of infectious disease mortality, mainly occurs in developing countries; however, its diagnosis still relies on conventional methods that are expensive or inaccurate and require infectious sputum samples. Here, we propose a safe, cost-effective and accurate electrochemical biosensor for TB diagnosis that directly detects the circulating biomarker CFP10 in serum with a gold electrode-based system. We selected an ssDNA aptamer that specifically binds to the CFP10 protein (Kd = 92.8 nM) and used ferri/ferrocyanide and methylene blue as label-free redox coupled agents for the electrochemical signal by fabricating the gold electrode modified with MB-bound aptamer. The developed sensor could be used to successfully quantify CFP10 within short turnaround time of 1 h in buffer and serum-spiked conditions with markedly low detection limits of 3.25 fM and 6.92 fM, respectively. Clinical application using 72 non-infectious serum samples from healthy controls and patients with active TB showed sensitivity of 64.58%, specificity of 95.83%, and accuracy of 86.81%. Additionally, the signal intensities of the sensor increased with the acid-fast bacillus indices of the sample, indicating that they could be used to determine the severity of TB. As a result, this novel and low-cost aptamer-based electrochemical sensor has the potential to be used for the early-stage exclusion and treatment of patients with active TB in resource-limited countries while avoiding the risk of infection by using non-infectious serum samples. | - |
dc.language | eng | - |
dc.publisher | 포항공과대학교 | - |
dc.title | Development of Safe and Sensitive Electrochemical Aptasensor for Active Tuberculosis Diagnosis | - |
dc.type | Thesis | - |
dc.contributor.college | 시스템생명공학부 | - |
dc.date.degree | 2024- 8 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
library@postech.ac.kr Tel: 054-279-2548
Copyrights © by 2017 Pohang University of Science ad Technology All right reserved.