Open Access System for Information Sharing

Login Library

 

Thesis
Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.author소재인-
dc.date.accessioned2024-08-23T16:33:00Z-
dc.date.available2024-08-23T16:33:00Z-
dc.date.issued2024-
dc.identifier.otherOAK-2015-10630-
dc.identifier.urihttp://postech.dcollection.net/common/orgView/200000806038ko_KR
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/124020-
dc.descriptionMaster-
dc.description.abstractTuberculosis (TB), the leading cause of infectious disease mortality, mainly occurs in developing countries; however, its diagnosis still relies on conventional methods that are expensive or inaccurate and require infectious sputum samples. Here, we propose a safe, cost-effective and accurate electrochemical biosensor for TB diagnosis that directly detects the circulating biomarker CFP10 in serum with a gold electrode-based system. We selected an ssDNA aptamer that specifically binds to the CFP10 protein (Kd = 92.8 nM) and used ferri/ferrocyanide and methylene blue as label-free redox coupled agents for the electrochemical signal by fabricating the gold electrode modified with MB-bound aptamer. The developed sensor could be used to successfully quantify CFP10 within short turnaround time of 1 h in buffer and serum-spiked conditions with markedly low detection limits of 3.25 fM and 6.92 fM, respectively. Clinical application using 72 non-infectious serum samples from healthy controls and patients with active TB showed sensitivity of 64.58%, specificity of 95.83%, and accuracy of 86.81%. Additionally, the signal intensities of the sensor increased with the acid-fast bacillus indices of the sample, indicating that they could be used to determine the severity of TB. As a result, this novel and low-cost aptamer-based electrochemical sensor has the potential to be used for the early-stage exclusion and treatment of patients with active TB in resource-limited countries while avoiding the risk of infection by using non-infectious serum samples.-
dc.languageeng-
dc.publisher포항공과대학교-
dc.titleDevelopment of Safe and Sensitive Electrochemical Aptasensor for Active Tuberculosis Diagnosis-
dc.typeThesis-
dc.contributor.college시스템생명공학부-
dc.date.degree2024- 8-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Views & Downloads

Browse