DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, KH | - |
dc.contributor.author | Jeong, SH | - |
dc.contributor.author | Kim, DE | - |
dc.contributor.author | Park, IS | - |
dc.contributor.author | Chung, CW | - |
dc.contributor.author | Kang, BK | - |
dc.date.accessioned | 2015-06-25T03:29:28Z | - |
dc.date.available | 2015-06-25T03:29:28Z | - |
dc.date.created | 2009-02-28 | - |
dc.date.issued | 2002-03 | - |
dc.identifier.issn | 0034-6748 | - |
dc.identifier.other | 2015-OAK-0000002497 | en_US |
dc.identifier.uri | https://oasis.postech.ac.kr/handle/2014.oak/12790 | - |
dc.description.abstract | The U10 undulator for the Pohang Light Source was measured with a pulsed wire measurement (PWM) method. By adjusting the aperture of the slotted optical switch (SOS) for PWM, the sensitivity of SOS output to the wire displacement improved significantly. A calibration table, which translates the output voltage to the displacement of wire, was obtained and the linearity of the PWM was enhanced using this table. The magnetic-field profile of the U10 undulator measured with the PWM method agrees well with that measured with Hall probe mapping. The effect of the wire dispersion on PWM is also discussed. (C) 2002 American Institute of Physics. | - |
dc.description.statementofresponsibility | open | en_US |
dc.language | English | - |
dc.publisher | AMER INST PHYSICS | - |
dc.relation.isPartOf | REVIEW OF SCIENTIFIC INSTRUMENTS | - |
dc.rights | BY_NC_ND | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.0/kr | en_US |
dc.title | Improvement of the pulsed wire method for undulator magnetic-field measurement | - |
dc.type | Article | - |
dc.contributor.college | 전자전기공학과 | en_US |
dc.identifier.doi | 10.1063/1.1420755 | - |
dc.author.google | Park, KH | en_US |
dc.author.google | Jeong, SH | en_US |
dc.author.google | Kang, BK | en_US |
dc.author.google | Chung, CW | en_US |
dc.author.google | Park, IS | en_US |
dc.author.google | Kim, DE | en_US |
dc.relation.volume | 73 | en_US |
dc.relation.issue | 3 | en_US |
dc.relation.startpage | 1442 | en_US |
dc.relation.lastpage | 1444 | en_US |
dc.contributor.id | 10071834 | en_US |
dc.relation.journal | REVIEW OF SCIENTIFIC INSTRUMENTS | en_US |
dc.relation.index | SCI급, SCOPUS 등재논문 | en_US |
dc.relation.sci | SCI | en_US |
dc.collections.name | Conference Papers | en_US |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | REVIEW OF SCIENTIFIC INSTRUMENTS, v.73, no.3, pp.1442 - 1444 | - |
dc.identifier.wosid | 000174182800025 | - |
dc.date.tcdate | 2019-01-01 | - |
dc.citation.endPage | 1444 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1442 | - |
dc.citation.title | REVIEW OF SCIENTIFIC INSTRUMENTS | - |
dc.citation.volume | 73 | - |
dc.contributor.affiliatedAuthor | Kang, BK | - |
dc.identifier.scopusid | 2-s2.0-0036494301 | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.wostc | 5 | - |
dc.description.scptc | 7 | * |
dc.date.scptcdate | 2018-10-274 | * |
dc.type.docType | Article; Proceedings Paper | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalResearchArea | Physics | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
library@postech.ac.kr Tel: 054-279-2548
Copyrights © by 2017 Pohang University of Science ad Technology All right reserved.