Detection of formaldehyde vapor using mercaptophenol-coated piezoresistive cantilevers
SCIE
SCOPUS
- Title
- Detection of formaldehyde vapor using mercaptophenol-coated piezoresistive cantilevers
- Authors
- Seo, H; Jung, S; Jeon, S
- Date Issued
- 2007-10-01
- Publisher
- ELSEVIER SCIENCE SA
- Abstract
- Piezoresistive cantilevers coated with mercaptophenol self-assembled monolayers were used to detect formaldehyde vapor at room temperature. The three isomers of mercaptophenol, namely 2-, 3-, and 4-mercaptophenol, were tested as probe molecules. The 3 -mercaptophenol -coated cantilever showed the largest deflection due to high reactivity between formaldehyde and 3-mercaptophenol. When the 3 -merc aptophenol -coated cantilever was exposed to interferents such as benzene, toluene, p-xylene, water, or ethanol, the deflection direction of the cantilever was the opposite of that induced by the chemical reaction with formaldehyde, indicating that 3-mercaptophenot is very specific to formaldehyde. The detection limit of the 3-mercaptophenol -coated cantilever was determined to be better than 0.01 ppm. (C) 2007 Elsevier B.V. All rights reserved.
- Keywords
- formaldehyde; mercaptophenol; piezoresistive cantilever; MICROCANTILEVER SENSORS; GAS SENSOR; AMBIENT; SYSTEM
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/23127
- DOI
- 10.1016/j.snb.2007.04.004
- ISSN
- 0925-4005
- Article Type
- Article
- Citation
- SENSORS AND ACTUATORS B-CHEMICAL, vol. 126, no. 2, page. 522 - 526, 2007-10-01
- Files in This Item:
- There are no files associated with this item.