Open Access System for Information Sharing

Login Library

 

Article
Cited 12 time in webofscience Cited 14 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
DC FieldValueLanguage
dc.contributor.authorKIM, MINJAE-
dc.contributor.authorGANG, YONG GU-
dc.contributor.authorCHA, KYOUNG JE-
dc.contributor.authorKIM, DONG SUNG-
dc.contributor.authorCHUNG, WAN KYUN-
dc.date.accessioned2018-05-04T02:48:37Z-
dc.date.available2018-05-04T02:48:37Z-
dc.date.created2018-02-12-
dc.date.issued2017-12-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/41356-
dc.description.abstractSurface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user's movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclosed in wet electrodes restricts spatial resolution, and these conventional bulky systems limit natural movements. In this paper, a microneedle-based high-density electrode array on a circuit integrated flexible substrate for sEMG is proposed. Microneedles allow for high spatial resolution without requiring conductive substances, and flexible substrates guarantee stable skin-electrode contact. Moreover, a compact signal processing system is integrated with the electrode array. Therefore, sEMG measurements are comfortable to the user and do not interfere with the movement. The system performance was demonstrated by testing its operation and estimating motion using a Gaussian mixture model-based, simplified 2D spatial pattern.-
dc.languageEnglish-
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)-
dc.relation.isPartOfSensors-
dc.titleWireless sEMG System with a Microneedle-Based High-Density Electrode Array on a Flexible Substrate-
dc.typeArticle-
dc.identifier.doi10.3390/s18010092-
dc.type.rimsART-
dc.identifier.bibliographicCitationSensors, v.18, no.1, pp.92 - 103-
dc.identifier.wosid000423286300091-
dc.date.tcdate2019-02-01-
dc.citation.endPage103-
dc.citation.number1-
dc.citation.startPage92-
dc.citation.titleSensors-
dc.citation.volume18-
dc.contributor.affiliatedAuthorKIM, MINJAE-
dc.contributor.affiliatedAuthorGANG, YONG GU-
dc.contributor.affiliatedAuthorKIM, DONG SUNG-
dc.contributor.affiliatedAuthorCHUNG, WAN KYUN-
dc.identifier.scopusid2-s2.0-85040020246-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc1-
dc.description.isOpenAccessY-
dc.type.docTypeArticle-
dc.subject.keywordPlusMYOELECTRIC CONTROL-
dc.subject.keywordPlusSILICON-
dc.subject.keywordPlusROBUST-
dc.subject.keywordAuthorsurface electromyography-
dc.subject.keywordAuthormicroneedle array electrode-
dc.subject.keywordAuthorhigh-density electrode array-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

정완균CHUNG, WAN KYUN
Dept of Mechanical Enginrg
Read more

Views & Downloads

Browse