Open Access System for Information Sharing

Login Library

 

Article
Cited 17 time in webofscience Cited 18 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorKwon, Donghoon-
dc.contributor.authorLee, Hyeonjeong-
dc.contributor.authorYoo, Hojin-
dc.contributor.authorHwang, Jeongin-
dc.contributor.authorLee, Dongkyu-
dc.contributor.authorJeon, Sangmin-
dc.date.accessioned2018-06-15T05:32:49Z-
dc.date.available2018-06-15T05:32:49Z-
dc.date.created2017-12-21-
dc.date.issued2018-01-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/50589-
dc.description.abstractWe developed a simple method for enrofloxacin detection in water and milk using a personal glucose meter (PGM). After mixing a test sample with Escherichia coli (E. coli) in lysogeny broth (LB) and glucose, the amount of glucose consumed (change in concentration) by bacterial metabolism was measured using the PGM. The antibacterial activity of enrofloxacin obstructs bacterial metabolism and so reduces glucose consumption in proportion to the enrofloxacin concentration. The limit of detection for enrofloxacin in both matrices was 5 ng/mL and the assay time was 2 h. Further, the change in glucose concentration could be determined qualitatively by the naked eye using glucose test strips for high-throughput screening. (C) 2017 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE SA-
dc.relation.isPartOfSENSORS AND ACTUATORS B-CHEMICAL-
dc.subjectPERFORMANCE LIQUID-CHROMATOGRAPHY-
dc.subjectASSAY-
dc.subjectAPTAMER-
dc.subjectACID-
dc.subjectMEAT-
dc.titleFacile method for enrofloxacin detection in milk using a personal glucose meter-
dc.typeArticle-
dc.identifier.doi10.1016/j.snb.2017.07.118-
dc.type.rimsART-
dc.identifier.bibliographicCitationSENSORS AND ACTUATORS B-CHEMICAL, v.254, pp.935 - 939-
dc.identifier.wosid000413308000113-
dc.date.tcdate2019-02-01-
dc.citation.endPage939-
dc.citation.startPage935-
dc.citation.titleSENSORS AND ACTUATORS B-CHEMICAL-
dc.citation.volume254-
dc.contributor.affiliatedAuthorLee, Hyeonjeong-
dc.contributor.affiliatedAuthorJeon, Sangmin-
dc.identifier.scopusid2-s2.0-85026749411-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc1-
dc.type.docTypeArticle-
dc.subject.keywordPlusPERFORMANCE LIQUID-CHROMATOGRAPHY-
dc.subject.keywordPlusASSAY-
dc.subject.keywordPlusAPTAMER-
dc.subject.keywordPlusACID-
dc.subject.keywordPlusMEAT-
dc.subject.keywordAuthorEnrofloxacin-
dc.subject.keywordAuthorPersonal glucose meter-
dc.subject.keywordAuthorBacteria-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

전상민JEON, SANGMIN
Dept. of Chemical Enginrg
Read more

Views & Downloads

Browse