Open Access System for Information Sharing

Login Library

 

Article
Cited 1 time in webofscience Cited 0 time in scopus
Metadata Downloads

Rationale and Design of a Wearable Cardiopulmonary Monitoring System for Improving the Efficiency of Critical Care Monitoring SCIE SCOPUS

Title
Rationale and Design of a Wearable Cardiopulmonary Monitoring System for Improving the Efficiency of Critical Care Monitoring
Authors
Lee, JinaHwang, You-MiPark, Sung-Min
Date Issued
2023-12
Publisher
MDPI
Abstract
Despite the recent development of wearable cardiopulmonary monitoring devices and their necessity in clinical settings, the evidence regarding their application in real-world intensive care units (ICUs) is limited. These devices have notable problems, such as inefficient manufacturing and cumbersome hardware for medical staff and patients. In this study, we propose a simplified cardiopulmonary monitoring system and present a protocol for a single-center prospective study to evaluate the efficacy of the proposed system compared with those from the conventional monitoring system. The system was designed to continuously measure electrocardiogram, respiration rate, and oxygen saturation in a stand-alone device with an intuitive data visualization platform and automatic data collection. The accuracy of the data measured from the proposed device will be pre-validated by comparing them with those from the reference device. Medical staff from the St. Vincent’s Hospital ICU will complete a five-point Likert-type scale questionnaire regarding their experience with conventional ICU monitoring systems. The result will be compared with the second questionnaire conducted after deploying the system. Since this is a study proposal paper, we do not have any data on this study yet. However, compared with the conventional patient monitoring system, the proposed device should be a promising method to relieve medical staff fatigue and that of the patients who must wear and attach the monitoring device for a long time.
URI
https://oasis.postech.ac.kr/handle/2014.oak/119757
DOI
10.3390/app132413101
Article Type
Article
Citation
Applied Sciences-basel, vol. 13, no. 24, page. 13101, 2023-12
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

박성민PARK, SUNG MIN
Dept. Convergence IT Engineering
Read more

Views & Downloads

Browse